Lv Yuanlu, He Wuzhong. Analysis on CP Failure of Long-distance Pipeline[J]. Oil & Gas Storage and Transportation, 1999, 18(8): 28-30.
Citation: Lv Yuanlu, He Wuzhong. Analysis on CP Failure of Long-distance Pipeline[J]. Oil & Gas Storage and Transportation, 1999, 18(8): 28-30.

Analysis on CP Failure of Long-distance Pipeline

More Information
  • Received Date: March 02, 1999
  • Available Online: August 22, 2023
  • A number of CP failures of long-distance pipeline are analyzed. The CP failures are divided into three categories: the first is that of pententiosat, cable, referrence electrod, and CP system; the second is that of isolated flange and external coating; and the third is that of interferrence of AC or DC, bridging with some metal, and that of having been induced by other construction. The different trouble shooting methods are put forward in the paper.
  • [1]
    唐明华: 油气管道阴极保护, 石油工业出版社(北京), 1986。
    [2]
    何悟忠: 东北管道存在的问题与思考, 油气储运, 1998, 17(4)。
    [3]
    何悟忠 王梦成: 管道保护工, 石油工业出版社(北京), 1998。

Catalog

    Article views PDF downloads Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return