Li Cai, Su Zhongxun. Method for Monitoring and Calculating the Proportional Calorific Capacity of Mixed Crude[J]. Oil & Gas Storage and Transportation, 1992, 11(3): 2-13, 18.
Citation: Li Cai, Su Zhongxun. Method for Monitoring and Calculating the Proportional Calorific Capacity of Mixed Crude[J]. Oil & Gas Storage and Transportation, 1992, 11(3): 2-13, 18.

Method for Monitoring and Calculating the Proportional Calorific Capacity of Mixed Crude

More Information
  • Received Date: September 15, 1991
  • Available Online: August 27, 2023
  • In order to determine the proportional calorific capacity of mixed cr-ude in oil pipeline on time, tlie author puts forward a meth od for calculating the proportional calorific capacity of mixed crude Ly way of using weighted calculation on the calorific capacity data of crude sample. By comparing qua-ntitative monitoring data with calculating results, it has been proved that the calculating method in the paper has a good relation with the practical monitoring proportional calorific capacity and tempreture of mixed crude, and that the difference is less than 5%. It has been proved too by calculation and analysis that this method has an enough precision and has a practical value on engineering for preparing oil pipeline operational plan and pred-etermining oil pipeline operational program.
  • [1]
    李才. 测定含蜡原油的比热容. 油气储运, 1982, 1(2): 1~8
    [2]
    李才. 含蜡原油比热容变化对加热输送的影响. 油田地面工程, 1984, 10(4)
    [3]
    严大凡. 输油管道设计与管理. 北京: 石油工业出版社, 1986

Catalog

    Article views PDF downloads Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return