Jia Yi. Influenee of pipe Diameter on the Whole Heat Transfer Coefficient[J]. Oil & Gas Storage and Transportation, 1991, 10(5): 54-58.
Citation: Jia Yi. Influenee of pipe Diameter on the Whole Heat Transfer Coefficient[J]. Oil & Gas Storage and Transportation, 1991, 10(5): 54-58.

Influenee of pipe Diameter on the Whole Heat Transfer Coefficient

  • The whole heat transfer coefficient is an important factor in the calculation of heat transfer for underground heated ojl pipeline. The paper analyzes the influence of pipe diameter on it and puts forward the practical calculating formula of the whole heat transfer coefficient for oil pipeline. It may be referenced for the engineering design.