YAN Wencan, XU Ming. Development and application of mobile gas flowrate calibration equipment[J]. Oil & Gas Storage and Transportation, 2014, 33(4): 418-421. DOI: 10.6047/j.issn.1000-8241.2014.04.016
Citation: YAN Wencan, XU Ming. Development and application of mobile gas flowrate calibration equipment[J]. Oil & Gas Storage and Transportation, 2014, 33(4): 418-421. DOI: 10.6047/j.issn.1000-8241.2014.04.016

Development and application of mobile gas flowrate calibration equipment

  • Based on the design practices worldwide, and considering the actual demands, Sinopec innovated a mobile gas flowrate calibration equipment. The equipment can be used to effectively calibrate gas flowmeters and supplement the gas flowrate traceability and transmission system. It is designed, for the first time, with three standard braches and the working flowrate range from 20 m3/hr to 8 000 m3/hr. A high-accuracy turbine flowmeter is chosen as the standard, and an ultrasonic flowmeter for verification. Advanced forcible seal ball valves and axial-flow control valves are installed to close branches and control flowrate. By uncertainty evaluation and testing, the equipment is proved with an uncertainty less than 0.33% (k=2), fully meeting the design requirements.