YANG Baoshan, ZHANG Wei. Failure Analysis on Longitudinal Finned Heat Exchanger and Technical Reform[J]. Oil & Gas Storage and Transportation, 2005, 24(3): 44-46. DOI: 10.6047/j.issn.1000-8241.2005.03.013
Citation: YANG Baoshan, ZHANG Wei. Failure Analysis on Longitudinal Finned Heat Exchanger and Technical Reform[J]. Oil & Gas Storage and Transportation, 2005, 24(3): 44-46. DOI: 10.6047/j.issn.1000-8241.2005.03.013

Failure Analysis on Longitudinal Finned Heat Exchanger and Technical Reform

  • Take the technical reform on longitudinal finned tubular oil/heating agent heat exchanger operated in # 2 Platform of Chengdao Oilfield Center as an example, this paper analyzes 3 failure modes of this kind of heater and presents relative improvement measures. The operation efficiency for the improved device shows that the service life is 2 times of unimproved exchanger with a high operating stability.