Gu Ming. Fault Analysis and Trouble Shooting of 4650 kW Heat Medium Heater[J]. Oil & Gas Storage and Transportation, 2000, 19(10): 49-51. DOI: 10.6047/j.issn.1000-8241.2000.10.014
Citation: Gu Ming. Fault Analysis and Trouble Shooting of 4650 kW Heat Medium Heater[J]. Oil & Gas Storage and Transportation, 2000, 19(10): 49-51. DOI: 10.6047/j.issn.1000-8241.2000.10.014

Fault Analysis and Trouble Shooting of 4650 kW Heat Medium Heater

  • Some faults existed in 4650 kW heat medium heater, such as fall-off of refractory liner, insulating layer breaking of outer ignition system and heat medium oxidation, have been analyzed in initial pump station of Zhongyuan Oilfield-Luoyang oil pipeline. The relative measures to solve these problems are put forward according to the analytical results.