浮顶油罐转动浮梯损坏原因分析
Analysis on the Rotative Ladder Deformation Accident of A Floating Roof Tank
-
摘要: 以山东邹城输油公司临邑站14号5×104 m3浮顶油罐遭受暴风雨袭击后, 其转动浮梯受损为例, 剖析出浮顶油罐转动浮梯的损坏主要是由于储罐所处的地理位置、气候变化、储罐高位运行、转动浮梯在高度方向运动时有限的限制, 及空气动力作用等因素造成的。并提出只有严格执行有关的技术规范和操作规程, 完善储罐技术指标的测评, 做好油罐的技术改造工作, 加强科技管理, 才能防患于未然。Abstract: A site investigation has been made on the accident of rotative ladder deformation in a floating roof tank in Linyi pump station. The investigative and analytical results show that there are three main causes for the accident: the location of tank, changing weather, and high tank-level. Some suggestions that working in accordance with relative codes and regulations, improving the evaluation of indexes for tank, technical reform, and enhancing management in order to protect against the accident be set forth.