阴极保护状态下管道特殊位置的电位测量
Potential Measurement at pipeline specific parts under cathodic protection
-
摘要: 阴极保护效果直接关系到埋地管道的寿命和运行安全。在管道特殊部位, 采用常规方法评估阴极保护效果往往产生偏差, 给安全运行留下隐患。通过对测试数据的分析, 指出管道特殊位置产生问题的原因, 为地面测试管-地电位评价法提供了有益的补充和借鉴。Abstract: The result of cathodic protection has direct relationship with buried pipeline s life span and operation safety. Regular method used to evaluate the result of cathodic protection at pipeline specific parts often caused deviation and left some hidden troubles to safety operation. By analyzing the test data, pointed out the reason occurred at the specific parts of the pipeline, which put forward a beneficial supplement and reference for the evaluation method on ground test of pipe-soil potential.