The Application of Vacuum Priming in Fire Extinguish of Oil Tank Farm
-
摘要: 油库固定式消防系统中, 现有的PH型泡沬混合器有很大局限性, 由于其出口端压力必须保持零或负压,因而使消防水泵与消防水罐之间罐低泵高相对位置不合理,造成消防水泵灌泵困难且易抽真空, 消防系统不能正常运行的缺点。本文以林源输油站消防系统为例, 采用真空灌泵技术, 解决了这一难题, 经现场多次灌泵和启泵试验, 均达到使用要求, 经济效道显著。Abstract: It is limited for existing PH foam mixer in the fixed fire prevention system of oil tank farm because its discharge pressure must be zero or minus, as a results the level of fire tank is lower than that of fire pumps between the fire pump and fire tank, it is difficult to prime, easy to suck in minus, hard to keep normal operation. In the paper taken Linyuan pump station as an example the vacuum priming was applied to resolve the problem, it is proved the operation reqirement was reached, the benifit was significant through field tests for pump priming and startup.