聂萍. 输油管道沿程散热损失实测与初步分析[J]. 油气储运, 1985, 4(4): 1-9.
引用本文: 聂萍. 输油管道沿程散热损失实测与初步分析[J]. 油气储运, 1985, 4(4): 1-9.
Nie Ping. Measrement and Preliminary Analysis of the Heat Losses on a Section of Oi Pipeline[J]. Oil & Gas Storage and Transportation, 1985, 4(4): 1-9.
Citation: Nie Ping. Measrement and Preliminary Analysis of the Heat Losses on a Section of Oi Pipeline[J]. Oil & Gas Storage and Transportation, 1985, 4(4): 1-9.

输油管道沿程散热损失实测与初步分析

Measrement and Preliminary Analysis of the Heat Losses on a Section of Oi Pipeline

  • 摘要: 通过对一个泵站的能量平衡浏试得知,其消耗能量(包括电和燃料油)中的65%均消耗在站问管道上。站间管道沿程散热损失的测试,不仅是“热诊断”, 也是挖掘节能潜力为寻求节能有效措施提供可靠的科学依据。

     

    Abstract: It has been known through the energy equilibrium measurement of a heated pipeline pump station that 65% of the energy consumed is lost on the pipeline between two stations. Such a measurement as mentioned above is not only"A heat diagnosis", but also a scientific base for working out some effective measures to save energy.

     

/

返回文章
返回