油气储运工程中压缩机厂房的防雷设计

Lightning protection design of compressor chamber

  • 摘要: 针对油气储运工程中压缩机厂房的防雷问题,以工程设计标准为基本依据,分析了压缩机厂房爆炸危险场所划分、防雷分类和防雷措施,探讨了放空管对压缩机厂房防雷设计的影响。压缩机厂房按照第二类防雷建筑物进行直击雷防护,使钢结构厂房从接闪器、引下线再到接地装置形成持久电气通路。当钢结构压缩机厂房金属屋面的厚度大于0.5 mm时,可以直接作为接闪器;建筑物的钢柱等金属构件宜作为引下线,其平均间距不大于18 m;将敷设在结构条基等混凝土基础内的自然接地体作为接地装置,并围绕建筑物设置人工环形接地体。压缩机放空管装设阻火器且壁厚在6 mm以上,可以作为接闪器,安装避雷针的必要性不大,但需要防止放空管与屋面防雷装置虚接。

     

    Abstract: In the light of the lighting protection of compressor chamber, the classifications of explosive risk areas, sort of lighting protection and lighting protection measures are analyzed based on the engineering design standards, and the influence of vent pipe on the lighting protection design of compressor chamber is discussed. The direct lightning stroke protection of compressor chamber should be in accordance with the Ⅱ-class lightning-resisting building, which can make steel structure chamber form a persistent electrical pathway from terminal system to downlead to grounding device. The metal roof of steel structure compressor chamber can be taken as a terminal system when its thickness is more than 0.5 mm; the metal member of building such as steel columns may be taken as a downlead and the average separation distance between them should not be more than 18 m; the natural grounding laid in the concrete foundation such as strip footing, etc. can be taken as a grounding device, and the artificial annular grounding should be constructed around buildings. The vent pipe of compressor installed with flame arrestor (wall thickness is more than 6 mm) can be taken as a terminal system without installing lightning arrester, but the virtual connection between the vent pipe and the lighting protection device on the roof should be prevented.

     

/

返回文章
返回