Treatment to oil injection failure of open-circuit pilot valve of Shafer pneumatic-hydraulic actuator

  • 摘要: 为了推动油气管道场站区域化管理模式的发展,提升运行人员处理进口设备故障的能力水平,针对生产运行过程中10726-S型Shafer气液联动执行机构发生的两起同类型典型喷油故障,对该型号执行机构的主要部件功能、正常状态下气路工作原理、执行场站ESD系统关阀命令时的气路工作原理进行分析,深入查找设备喷油故障原因。结合现场设备运行状况及日常维护保养情况,提出具体的故障处理方法和切实有效的预防措施,以保障设备安全平稳运行。研究成果可为今后Shafer气液联动执行机构出现各类故障的原因判断及维修处理提供理论基础,并提升场站运维人员的故障处理能力。

     

    Abstract: Two typical oil injection failures of the same type occurred to 10726-S pneumatic-hydraulic actuators during production and operation. In order to better promote the development of the regional management mode of oil/gas pipelines and stations and improve the capability of the operators to treat failures of imported equipment, deep analysis was conducted to the functions of the main components of the 10726-s actuators, the operating principle of the gas circuit under normal conditions, and the operating principle of the gas circuit in performing the command of station ESD system for valve shutdown, so as to find out the root causes of oil injection failure. With reference to the operation status and the daily maintenance of field equipment, specific solutions and effective preventive measures were put forward to ensure the safe and stable operation of the equipment. Thus, the research results could provide theoretical basis for judging the causes of various faults and the maintenance treatment methods of various failures of the Shafer pneumatic-hydraulic actuator and they are also helpful to enhance the fault treatment capability of the operation and maintenance staffs.

     

/