唐建峰, 金新明, 周军逸, 杨文刚, 崔健, 张豪杰. FLNG填料塔内气体分布器适应性试验[J]. 油气储运, 2018, 37(7): 822-830. DOI: 10.6047/j.issn.1000-8241.2018.07.016
引用本文: 唐建峰, 金新明, 周军逸, 杨文刚, 崔健, 张豪杰. FLNG填料塔内气体分布器适应性试验[J]. 油气储运, 2018, 37(7): 822-830. DOI: 10.6047/j.issn.1000-8241.2018.07.016
TANG Jianfeng, JIN Xinming, ZHOU Junyi, YANG Wengang, CUI Jian, ZHANG Haojie. Compatibility test of gas distributor in the FLNG packed tower[J]. Oil & Gas Storage and Transportation, 2018, 37(7): 822-830. DOI: 10.6047/j.issn.1000-8241.2018.07.016
Citation: TANG Jianfeng, JIN Xinming, ZHOU Junyi, YANG Wengang, CUI Jian, ZHANG Haojie. Compatibility test of gas distributor in the FLNG packed tower[J]. Oil & Gas Storage and Transportation, 2018, 37(7): 822-830. DOI: 10.6047/j.issn.1000-8241.2018.07.016

FLNG填料塔内气体分布器适应性试验

Compatibility test of gas distributor in the FLNG packed tower

  • 摘要: 填料塔作为现代化工工艺生产中不可或缺的处理设备,其性能在一定程度上受到气体分布器的影响,均布效果优良的气体分布器可一定程度提高填料塔的吸收效果。双切向环流式气体分布器因其压降低、液沫夹带量小、气体分布效果较好等特性而被广泛应用于填料塔内。以双切向环流式气体分布器为研究对象,分别选取静止状态和16 s周期下横摇、纵摇、艏摇8°及横荡、纵荡、垂荡150 mm的工况进行实验研究,对海上晃动条件下FLNG填料塔内气体分布器适应性开展研究。结果表明:在6个自由度晃动中,除横荡工况下气体分布不均匀,其系数较静止时增加3.03%,其余晃动工况对气体均布有一定的促进效果,故气体分布器在FLNG填料塔内的设计可与陆上保持一致。

     

    Abstract: The packed tower is the indispensable processing equipment in modern chemical technique and production, and its performance is partly influenced by the gas distributor. The gas distributor with great uniform distribution effect can, in a way, enhance the absorption effect of packed tower. The twin-tangential annular flow gas distributor is widely applied in packed towers owing to its advantages of small pressure drop, little liquid entrainment and better gas distribution. In this paper, the twin-tangential annular flow gas distributor was taken as the study object to conduct the experimental study on the adaptability of gas distributor in the FLNG packed tower in the sea conditions of sloshing, including quiescent condition, rolling, pitching and yawing by 8 degrees and swaying, surging and heaving by 150 mm in the cycle of 16 s. It is shown that 6 freedom-degree sloshes except the swaying promote the uniform gas distribution. In the working condition of swaying, the gas distribution is not uniform and its coefficient is 3.03% higher than that of quiescent condition. Therefore, the design of gas distributor in the FLNG packed tower can be consistent with that on the land.

     

/