李雪洁, 刘翠伟, 李玉星. 输气站场自用气系统优化设计[J]. 油气储运, 2015, 34(3): 271-274. DOI: 10.6047/j.issn.1000-8241.2015.03.010
引用本文: 李雪洁, 刘翠伟, 李玉星. 输气站场自用气系统优化设计[J]. 油气储运, 2015, 34(3): 271-274. DOI: 10.6047/j.issn.1000-8241.2015.03.010
LI Xuejie, LIU Cuiwei, LI Yuxing. Optimized design of self-consumption gas system in gas compressor station[J]. Oil & Gas Storage and Transportation, 2015, 34(3): 271-274. DOI: 10.6047/j.issn.1000-8241.2015.03.010
Citation: LI Xuejie, LIU Cuiwei, LI Yuxing. Optimized design of self-consumption gas system in gas compressor station[J]. Oil & Gas Storage and Transportation, 2015, 34(3): 271-274. DOI: 10.6047/j.issn.1000-8241.2015.03.010

输气站场自用气系统优化设计

Optimized design of self-consumption gas system in gas compressor station

  • 摘要: 输气管道站场自用气系统多采用两级调压的模式,以实现将气体压力由干线压力调至几千帕至几百千帕的调压要求。针对该模式工艺流程复杂、设备多、投资大的缺点,以及不能适应中小型管道需求的问题,对原有自用气系统进行优化,结合自用气用量小的特点,利用管道的储气功能,为用户提供一个低压、稳定的气源,代替了调压阀的工作,从而简化了原设计中的三阀组结构。使用HYSYS软件对优化方案的节流温降进行计算,用缠绕电伴热带的方案代替了原设计中的电加热器。对优化方案中电动阀门的动作频率进行了计算,证明其动作频率远远低于原方案中调压阀的动作频率,减少了阀门磨损的可能,去掉了原设计中的过滤设备。研究结果可为输气站场自用气系统设计提供指导。

     

    Abstract: Two-stage pressure regulating mode is adopted in the self-consumption gas system in gas compressor station, so that the gas pressure can be regulated from the arterial pressure to a few or hundreds of kilopascal. Considering that this mode requires complicated process, more equipment and large investment, and is not applicable to small and medium sized pipes, original self-consumption gas system is optimized. In particular, since less gas volume is needed for self-consumption, the pipeline gas storage is adopted, instead of the pressure regulating valve, to provide users with a low-pressure and stable gas supply, thus simplifying the three valve structure in original design. HYSYS software is used to calculate the throttling temperature drop of the optimized design, and the winding electric tracing band is adopted to replace the electric heater in original design. The operating frequency of electric valve in the optimized design is calculated, providing that the operating frequency is far below that of pressure regulating valve in original design. Therefore, the possibility of the valve wear is reduced, and the filter plant in original design is removed. The research can provide a reference to the design of self-consumption gas system in gas compressor station.

     

/