SAFE压缩机组故障分析与处理措施
Failure Analysis and Trouble Shooting of SAFE Compressor Sets
-
摘要: 对CNG站赛福(SAFE)压缩机组级间温度升高和压力变化的问题进行了分析, 结果表明, 该故障为二级进气阀破损和二级排气阀漏气所致。提出了改造二级进气阀处理方案。针对冷却系统高位水箱冷却水溢出等问题, 提出了修复换热器、加强密封等技术措施。Abstract: In allusion to the higher interstage temperature and variable pressure for SAFE compressor sets in CNG station, a technical analysis on the problems is made.The analysis results show that damage of secondary air inlet valve and leakage of secondary air bleeding valve are major causes.Technical modifica-tion program for the secondary air inlet valve is presented.For issues about water overflow from top water container of cooling system.technical reform methods in repairing heat exchanger and enhancing sealing are proposed.