张石超, 项卫东. RF2/3BB36型压缩机喘振线的测试方法[J]. 油气储运, 2008, 27(7): 49-51. DOI: 10.6047/j.issn.1000-8241.2008.07.014
引用本文: 张石超, 项卫东. RF2/3BB36型压缩机喘振线的测试方法[J]. 油气储运, 2008, 27(7): 49-51. DOI: 10.6047/j.issn.1000-8241.2008.07.014
ZHANG Shichao, XIANG Weidong. Method for Testing the Surge Line of RF2/3BB36 Gas Compressor[J]. Oil & Gas Storage and Transportation, 2008, 27(7): 49-51. DOI: 10.6047/j.issn.1000-8241.2008.07.014
Citation: ZHANG Shichao, XIANG Weidong. Method for Testing the Surge Line of RF2/3BB36 Gas Compressor[J]. Oil & Gas Storage and Transportation, 2008, 27(7): 49-51. DOI: 10.6047/j.issn.1000-8241.2008.07.014

RF2/3BB36型压缩机喘振线的测试方法

Method for Testing the Surge Line of RF2/3BB36 Gas Compressor

  • 摘要: 以西气东输中卫压气站RF2BB36型压缩机喘振线的测试为例, 介绍了RF2/3BB36型压缩机喘振线的测试方法, 同时对该测试方法存在的优缺点和适用性进行了总结。

     

    Abstract: Take the test for the surge line of RF2/3BB36 Gas Compressor in Zhongwei Gas Compressor Station for example, the paper introduces the test method of the surge line. Strong and weak points of this test method are exposed during testing. Authors consider that by means of testing the surge line of the newly-installed gas compressor set, its field performance is verified and the surge parameters measured is inputted into anti-surge control program at one time so as to ensure safe running of the gas compressor sets.

     

/

返回文章