雅克拉-大涝坝气田凝析气的计量技术

Applied Metering Technology of Condensate Gas in Yakla-Dalaoba Gasfield

  • 摘要: 针对凝析气气质特性较为复杂, 给气田天然气计量仪表选型、使用及维护带来较大困难的情况, 以雅克拉-大涝坝凝析气田为例, 从凝析气气质特性、计量仪表工作环境、仪表特性等多个角度进行了分析, 讨论了适合凝析气田天然气不同计量要求的计量技术。

     

    Abstract: The result from experimental study displays that as the physical properties of condensate gas are very complicated, they brings about difficulties in type determination of metering instruments, meter operation and daily care of meters. Take the metering of condensate gas in Yakla-Dalaoba Gasfield for example, a multianalysis is carried out on the physical properties of condensate gas, operating environment of metering instruments and characteristic of meters, and metering technology for the different requirements of metering instruments suitable for condensate gasfield is discussed.

     

/