黄郑华, 李建华, 杨扬. 液化石油气空混气站危险性评价及安全措施[J]. 油气储运, 2006, 25(7): 48-52. DOI: 10.6047/j.issn.1000-8241.2006.07.012
引用本文: 黄郑华, 李建华, 杨扬. 液化石油气空混气站危险性评价及安全措施[J]. 油气储运, 2006, 25(7): 48-52. DOI: 10.6047/j.issn.1000-8241.2006.07.012
HUANG Zhenghua, LI Jianhua, . Evaluation on Fire and Explosion Hazards and Safety Measures of Station of Liquefied Petroleum Gas Mixed Air[J]. Oil & Gas Storage and Transportation, 2006, 25(7): 48-52. DOI: 10.6047/j.issn.1000-8241.2006.07.012
Citation: HUANG Zhenghua, LI Jianhua, . Evaluation on Fire and Explosion Hazards and Safety Measures of Station of Liquefied Petroleum Gas Mixed Air[J]. Oil & Gas Storage and Transportation, 2006, 25(7): 48-52. DOI: 10.6047/j.issn.1000-8241.2006.07.012

液化石油气空混气站危险性评价及安全措施

Evaluation on Fire and Explosion Hazards and Safety Measures of Station of Liquefied Petroleum Gas Mixed Air

  • 摘要: 采用美国DOW(道)化学公司火灾爆炸指数评价方法,对某液化石油气空混气站的固有火灾危险性、监控预警系统及其它消防安全措施进行了分析与评价,对存在的不安全问题,提出了针对性的措施和建议,可作为液化石油气空混站科学管理和安全操作的参考。

     

    Abstract: Analyses and evaluations are made on the inherent fire risks, watching alarm system and fire control measures in the station of liquefied petroleum gas (PLG) mixed air by use of the method of Dow Fire Index V7.0. Some pertinent safety measures and suggestions are put forward on the discovered safety problems, which can be applied as references to the scientific management and safety operation in the station of PLG mixed air.

     

/