三化输油管道低输量加剂运行分析

Field PPD-benefidated Testing on Lower Throughput Oil Pipeline

  • 摘要: 针对北三台至乌鲁木齐石化分输站三化输油管道输量低的现状, 提出了采用加注降凝剂提高管道输量的方法, 并对其实际应用效果进行了对比分析。指出优选加注降凝剂时必须先对管输油品热处理温度和温降速率进行判定, 然后再通过室内和现场工业性试验选定; 不同浓度下对应的降凝剂加注浓度也必须根据外界环境条件以及管道实际输送状况而定。

     

    Abstract: SanHua Oil Pipeline in Wulumuqi, Xingjiang is at lower throughput operated and in this case the PPD-beneficiated method to increase the oil throughput is put forward. The systematical laboratory and field tests are carried out and the modifying effect is analyzed. It is pointed out that the heating temperature and temperature drop rate of oil should be first determined when selecting PPD, then determined the candidate, in addition, the PPD's concentration has to be determined on the basis of ambient condition and actual pipeline transportation condition.

     

/