曾多礼. 格拉成品油管道火灾事故分析及预防[J]. 油气储运, 2004, 23(8): 40-41. DOI: 10.6047/j.issn.1000-8241.2004.08.013
引用本文: 曾多礼. 格拉成品油管道火灾事故分析及预防[J]. 油气储运, 2004, 23(8): 40-41. DOI: 10.6047/j.issn.1000-8241.2004.08.013
CENG Duoli. Fire Accident Analysis of Golmud-Lhasa Products Pipeline and Fire Control[J]. Oil & Gas Storage and Transportation, 2004, 23(8): 40-41. DOI: 10.6047/j.issn.1000-8241.2004.08.013
Citation: CENG Duoli. Fire Accident Analysis of Golmud-Lhasa Products Pipeline and Fire Control[J]. Oil & Gas Storage and Transportation, 2004, 23(8): 40-41. DOI: 10.6047/j.issn.1000-8241.2004.08.013

格拉成品油管道火灾事故分析及预防

Fire Accident Analysis of Golmud-Lhasa Products Pipeline and Fire Control

  • 摘要: 对格拉成品油管道4次火灾爆炸事故的原因进行了分析, 提出了建立健全严格的、操作性强的规章制度和防范措施, 加强管道安全管理和油料防火及消防常识教育, 定期开展消防演练, 加强管道硬件设施建设和加强作业区安全防范力度以及依靠社会力量保护管道安全等各项预防措施。

     

    Abstract: The case analysis on 4 fire accidents in Golmud-Lhasa Products Pipeline is made. To minimize the fire possibility, several countermeasures against fire are presented, including estab lishing and improving the fire control regulations and systems, necessary staff education and training on safety management and fire con-trol for products oil, regular exercise of fire control, inspection on suitability of pipeline and facilities, as well as safety and protection on pipeline and tankfarm and protection relying on the society.

     

/

返回文章