熊信勇, 姚喆, 郑斌, 黄长辉. 罐底板外壁阴极保护电位测量方法[J]. 油气储运, 2002, 21(9): 30-32, 57. DOI: 10.6047/j.issn.1000-8241.2002.09.009
引用本文: 熊信勇, 姚喆, 郑斌, 黄长辉. 罐底板外壁阴极保护电位测量方法[J]. 油气储运, 2002, 21(9): 30-32, 57. DOI: 10.6047/j.issn.1000-8241.2002.09.009
XIONG Xinyong, YAO Zhe, . The Study on Measurement Method of Protection Potential for Outer Shell of Tank Bottom Plate[J]. Oil & Gas Storage and Transportation, 2002, 21(9): 30-32, 57. DOI: 10.6047/j.issn.1000-8241.2002.09.009
Citation: XIONG Xinyong, YAO Zhe, . The Study on Measurement Method of Protection Potential for Outer Shell of Tank Bottom Plate[J]. Oil & Gas Storage and Transportation, 2002, 21(9): 30-32, 57. DOI: 10.6047/j.issn.1000-8241.2002.09.009

罐底板外壁阴极保护电位测量方法

The Study on Measurement Method of Protection Potential for Outer Shell of Tank Bottom Plate

  • 摘要: 根据国内普遍采用的罐底结构, 建立了一个直径为12m的模拟罐底板和相应的外加电流阴极保护系统。研究了各种罐底电位测量方法, 对测量结果进行了分析, 论述了各种测量过程中可能存在的测量误差。

     

    Abstract: On the basis of bottom structure of oil tank widely used in home, a 12-m-diameter simulated tank bottom plate and corresponding impressed current cathodic protection system are established. The various measurement methods on the potential of tank bottom are studied. The paper analyzes the measurement results, describes the measurement errors possibly existed in measurement methods.

     

/

返回文章