陈江波, 韩振江. 空压机排气管道存压问题分析与改进措施[J]. 油气储运, 2000, 19(6): 48-49. DOI: 10.6047/j.issn.1000-8241.2000.06.017
引用本文: 陈江波, 韩振江. 空压机排气管道存压问题分析与改进措施[J]. 油气储运, 2000, 19(6): 48-49. DOI: 10.6047/j.issn.1000-8241.2000.06.017
Chen Jiangbo, Han Zhenjiang. Analysis on Standing Pressure of Air-supply Pipe of Air Compressor and Trouble Shooting[J]. Oil & Gas Storage and Transportation, 2000, 19(6): 48-49. DOI: 10.6047/j.issn.1000-8241.2000.06.017
Citation: Chen Jiangbo, Han Zhenjiang. Analysis on Standing Pressure of Air-supply Pipe of Air Compressor and Trouble Shooting[J]. Oil & Gas Storage and Transportation, 2000, 19(6): 48-49. DOI: 10.6047/j.issn.1000-8241.2000.06.017

空压机排气管道存压问题分析与改进措施

Analysis on Standing Pressure of Air-supply Pipe of Air Compressor and Trouble Shooting

  • 摘要: 空气压缩机二级缸及排气管道的存压造成其零部件严重损坏, 影响了热媒炉的安全运行。通过分析故障原因, 提出了改进措施, 即在空压机上安装一套放气泄压系统, 可有效解决二级缸及排气管道存压的问题, 实际运行工况表明, 安装泄压系统后的空压机故障停机次数大幅度降低, 延长了设备的使用寿命, 保证了热媒炉的安全运行。

     

    Abstract: In the light of the standing pressure within the secondary cylinder of air compressor and air-supply pipe, it influences the safe operation of heat medium heater, an air relief system to eliminate the standing pressure has been adopted in the air-supply system. Actual operation of the system has shown that the shutdown frequency of air compressor has been greatly reduced, which is significantly beneficial to the heat medium heater.

     

/